Important Safety Alerts

Skip to main content

Safety Alerts and Communications

Important Safety Alerts

Important Safety Alerts

Field Safety Notice: Terumo Soft-Flow® Aortic Cannula with angled tip

09 Mar 2012

Medical device manufacturer, Terumo Cardiovascular Systems Corporation, has issued a Field Safety Notice concerning Soft-Flow® Aortic Cannula with angled tip.

During an in-house inspection, Terumo Cardiovascular Systems (Terumo CVS) identified an unintended hole in the side wall of the angled tip of a Soft-Flow® Aortic Cannula.

The manufacturer's investigation suggests that the defect occurred during the tip bending process. Potential hazards include the following:

  1. If the defect is noticed prior to insertion, patient risk is limited to those harms associated with substitution of the product and the resulting delay of the case.
  2. If the defect is not noticed before insertion, there is a potential for a constant, high pressure blood spray following insertion from the defect in the cannula tip and the operating pressure to which the cannula is typically exposed, leading to blood loss and an increased risk of blood exposure to the cardiac team.
  3. If the defect is discovered after insertion and requires replacement of the device, change-out of the product will be necessary. This could encompass:
    • Additional manipulation of the aorta and the risk of tissue damage, from a slight tear to a dissection requiring surgical intervention,
    • Small amounts of air could be entrained through the hole and into the aorta, leading to potential embolic events,
    • Delay of case and any harm that might relate to hypotension based on the duration of the replacement process and the stability of the patient during the process.

There has been no report of patient injury as a result of this issue. Terumo CVS is alerting its customers to stop using the affected devices.

According to the local supplier, affected devices have not been distributed in Hong Kong. If you are in possession of the products, please contact your supplier for necessary actions.

Top
Level Double-A conformance, W3C WAI Web Content Accessibility Guidelines 2.1(Thumbnail) Brand Hong Kong(Thumbnail)